Турбити метр Turb® 750 ИК
Модель: | 6315066 |
Наличие: | срок поставки 90 дней |
210 742.24 грн
Turbidity meter Turb® 750 IR
High-precision turbidity measuring devices for standardized measurement in drinking water and laboratory and industrial applications with AQA-based turbidity measurement.
-Backlit graphic display, 160 x 104 Pixel
-Quick response time
-Multiple measurements and evaluation of the measurement data with the intelligent reproducibility and plausibility check (IRPC)(IRPC)
-Function keys
-Comfortable menu-guided 3-point standard calibration
-Flexible calibration with 2 to 5 user-defined calibration points
-QuickCAL: 1-point-calibration at 10 NTU
-AQA, calibration interval and records with PC-documentation and LIMS connection
-For round cells with diam. 28 mm, volume min. 15 ml
-With RS 232 interface, USB
Scope of supply: Turbidity meter, 4 x batteries, wide range power supply, cable USB-A to USB-B mini, 6 x empty vials, sticker for orientation marking, calibration kit, cloth, manuals, CDROM with manual and PC software Turb® Data, inspection protocol
Nephelometrical turbidity measurement according to DIN EN ISO 7027-1.
Specifications
Light source: Infrared LED
Measuring range: 0 ... 1100 FNU/NTU
Resolution: 0.01 FNU/NTU in the range 0.00 ... 9.99
0.1 FNU/NTU in the range 10.00 ... 99.99
1 FNU/NTU in the range 100 ... 1000
Accuracy: 0.01 FNU/NTU or ±2 % of measured value
Reproducibility: <0.5 % of measured value
Type Turb® 750 IR
High-precision turbidity measuring devices for standardized measurement in drinking water and laboratory and industrial applications with AQA-based turbidity measurement.
-Backlit graphic display, 160 x 104 Pixel
-Quick response time
-Multiple measurements and evaluation of the measurement data with the intelligent reproducibility and plausibility check (IRPC)(IRPC)
-Function keys
-Comfortable menu-guided 3-point standard calibration
-Flexible calibration with 2 to 5 user-defined calibration points
-QuickCAL: 1-point-calibration at 10 NTU
-AQA, calibration interval and records with PC-documentation and LIMS connection
-For round cells with diam. 28 mm, volume min. 15 ml
-With RS 232 interface, USB
Scope of supply: Turbidity meter, 4 x batteries, wide range power supply, cable USB-A to USB-B mini, 6 x empty vials, sticker for orientation marking, calibration kit, cloth, manuals, CDROM with manual and PC software Turb® Data, inspection protocol
Nephelometrical turbidity measurement according to DIN EN ISO 7027-1.
Specifications
Light source: Infrared LED
Measuring range: 0 ... 1100 FNU/NTU
Resolution: 0.01 FNU/NTU in the range 0.00 ... 9.99
0.1 FNU/NTU in the range 10.00 ... 99.99
1 FNU/NTU in the range 100 ... 1000
Accuracy: 0.01 FNU/NTU or ±2 % of measured value
Reproducibility: <0.5 % of measured value
Type Turb® 750 IR
LLG | |
Тип | Turb® 750 IR |